• Fritsch GmbH Mahlen und Messen | Probenaufbereitung und Partikelmessung

    • Appareils
    • Solutions
    • Service
    • Actualites
    • Qui sommes-nous
    • Contact
    • Accueil
    • Contact
    • Imprimer
    • erp
    • English USA
    • English UK
    • Deutsch
    • French
    • Russian
    • IT
    • ES
    • Chinese
    • Japanese
    • Accueil
    • ·
    • Solutions
    • ·
    • Secteurs d'activités
    • ·
    • Produits alimentaires
    • ·
    • Reports from this industry
    • ·
    • Straw, hay, dried plants, herbal teas
      • Secteurs d'activités
        • Industria de la construcción
        • Biologie
        • Chimie
        • Mécanochimie
        • Secteur agricole et forestier
        • Géologie / minéralogie
        • Industries de la céramique / du verre
        • Matériaux synthétiques / textiles
        • Produits alimentaires
          • Reports from this industry
          • Grinding reports from this industry
        • Métallurgie
        • Environnement
        • Pharmacie
      • Moteur de recherche appareil
      • Protocoles de broyage

      Contact Applications Laboratory

      FRITSCH Applications Laboratory Ulrich Gerber
      Ulrich Gerber

      Phone: 0049 67 84 70 122

      gerber(at)fritsch.de

    • Les broyeurs FRITSCH dans les industries alimentaires

      Votre application – notre solution : en savoir plus sur les méthodes de préparation d'échantillons dans les industries alimentaires. Prenez connaissance de nos rapports d'application avec des conseils pour le broyage ou consultez notre base de données sur les protocoles de broyage avec de très nombreux exemples et des indications précises. - Rapports et protocoles de broyage ici en anglais -

       

      • Reports from this industry
      • Grinding reports from this industry

      Straw, hay, dried plants, herbal teas - are mostly very bulky samples

      A typical straw sample.

      The reasonably priced Cutting Mill PULVERISETTE 15 is to be recommended if:

      - only a few samples per week are to be comminuted

      - the sample amount is small

      - the linear expansion has been reduced via chaffing for example

      - if a low carry over of sample material to the next sample is tolerable

      - more time for cleaning is available

      Are the recommendations in regards to cleaning and expenditure of time higher though, the Universal-Cutting Mill PULVERISETTE 19 is implicitly to be recommended. Extremely positive effects on the cleaning have:

      • quick opening device for the housing
      • cutting rotor with V-cutting geometry only with smooth surfaces
      • cutting rotor removable without tools
      • sieve cassette removable without tools
      • standard and protected-funnels for long- and bulk solids without dead space

      Larger sample amounts or also a larger number of samples demand a fast throughput of the sample. The limiting element with cutting mills is the addition of bulky samples. Here the recommendation can only be to combine the Universal-Cutting Mill PULVERISETTE 19 with the cyclone separator. The cyclone separator generates an air current, which downright draws the bulky goods into the funnel (on the right side of the photo), draws it through the mill, thereby at the same time acts as a cooling current and finally separates the comminuted material into the sample bottle (pictured on the left side of the photo, connected to the black funnel). Everyone that is faced with this task and is familiar with the troubles of the comminution of straw is totally enthused after having once worked with this system.

      Straw was comminuted with a Universal Cutting Mill PULVERISETTE 19, equipped with a 0.5 mm sieve cassette. During the first test, the sample was processed without the cyclone separator, for the second test the cyclone separator was used. When comparing both finenesses, the sample processed with the cyclone separator contains slightly longer shares. In the air current generated by the cyclone separator, longer parts are rather aligned and pushed through the sieve.

      With the cyclone separator and a 0.25 mm sieve cassette, 1 kg dry straw was put through in 10 minutes. In order to understand this amount better, refer back to the volume of 1 kg uncomminuted.

      Additional uses for analogue applications for the Universal-Cutting Mill PULVERISETTE 19 are the comminution:

      • of herbs and herbal teas for analytical tasks
      • for drugs for the State Offices of Criminal Investigations, as a preparation for the qualitative and quantitative analysis
      • of herbs as a precursor for the extraction

      Downloads / Grinding reports / Links

      Download the FRITSCH-report as PDF-file

      Straw, hay, dried plants, herbal teas - are mostly very bulky samples

       

      Detailed grinding reports

      Straw

      back

    • Liens directs
    • Login
    • Contact
    • CGV
    • Mentions légales
    • Recommander page
    • Imprimer
    • Préparation d'échantillons
    • Mesure granulométrique
      • Contact / Service / Nouvelles

         

         

        Contact

        Conseil application

        Support technique

        Contact dans le monde

         

        Service

        Conseil application

        Support technique

        Votre application - notre solution

        Moteur de recherche appareil

        Protocoles de broyage

        Préparation d'échantillon gratuit

        Contact dans le monde

        Téléchargements

        Garantie en ligne

        Certificats QA

         

        Actualités

        Nouvelles

        Démonstrations itinérantes

        Séminaires

        Salons et expositions

      • Appareils pour la préparation d'échantillons

         

        Broyage

        Broyeurs planétaire

        Broyeurs à billes

        Broyeurs à couteaux

        Broyeurs à rotor / à marteaux

        Concasseurs à mâchoires / Broyeurs à disques

        Broyeur à mortier

         

        Tamisage

        Tamiseuses à vibration

        Tamiseuses à haut performance

         

        Division / Alimentation / Nettoyage

        Diviseur d'échantillon

        Trémies d'alimentation à vibrations

        Bains de nettoyage à ultrasons

      • Appareils pour mesure granulométrique

         

        Diffraction laser

        Plage de mesure 0,08 – 2000 µm

        Unité de mesure

        Dispersion par voie liquide

        Dispersion par voie sèche

        Dispersion par voie sèche par chute

        Dispersion par voie liquide pour petites quantités

        Logiciels

         

        Plage de mesure 0,01 – 2000 µm

        Unité de mesure

        Dispersion par voie liquide

        Dispersion par voie sèche

        Dispersion par voie sèche par chute

        Dispersion par voie liquide pour petites quantités

        Logiciels

         

        Diffusion dynamique de lumière DLS:

        Plage de mesure 1 nm – 6 µm

      • Liens

         

         

        Autres domaines

        www.fritsch-milling.com

        www.fritsch.de

        www.fritsch.com.ru

        www.fritsch.es

        www.fritsch-italy.it

        www.fritsch.com.sg

        www.fritsch.cn

        www.fritsch.jp

        www.fritsch.kr

         

        www.fritsch-sizing.fr

        www.fritsch-sizing.com

        www.fritsch-sizing.de

        www.fritsch-sizing.ru

        www.fritsch-sizing.es

        www.fritsch-sizing.it

        www.fritsch-sizing.com.sg

        www.fritsch-sizing.cn

        www.fritsch-sizing.jp

        www.fritsch-sizing.co.kr

      • Pour visiteurs déjà enregistrés

        Entrez votre adresse email et mot de passe :

        Mot de passe oublié ?

      • Please complete the form below for your account: